W100RIP − W200RIP 

WDESKLIGHTRIP − WDESK-L/R-RIP 

WINOX-L/R/2L-RIP − WTAB-L/R-RIP 

 

WEIGHT REPEATER 

version 1.10 

 

 

 

 

 

 

 
 
 
 
 
 

 

Summary of Contents for W100RIP

Page 1: ...ENGLISH ENGLISH ENGLISH ENGLISH W100RIP W200RIP WDESKLIGHTRIP WDESK L R RIP WINOX L R 2L RIP WTAB L R RIP WEIGHT REPEATER version 1 10 ...

Page 2: ...fication label and or serial number of the product misuse transformation alteration repair of products not carried out by Laumas personnel Laumas provides a 1 year warranty from the date of the delivery note on defects in material or manufacture of the battery GUIDELINES FOR PROPER DISPOSAL This symbol on the product or packaging indicates that This is electrical electronic equipment and cannot be...

Page 3: ...7 CHANGING VOLTAGE 115 VAC 230 VAC WDESK L R 7 INSTRUMENTS BACK TYPES 8 KEY TO P Q X TYPE CONNECTORS 8 KEY TO D TYPE CONNECTORS 9 RS485 SERIAL COMMUNICATION 10 RS232 SERIAL COMMUNICATION 10 LED SYMBOLS AND KEY FUNCTIONS 11 MENU MAP 12 SETPOINT 12 SYSTEM PARAMETERS 12 PROGRAMMING OF SYSTEM PARAMETERS 13 SERIAL COMMUNICATION SETTINGS 13 SETTING THE NUMBER OF DECIMALS 13 SETTING UNIT OF MEASURE 13 SE...

Page 4: ...TEMPORARY MENU UNLOCKING 17 DATA DELETION AND PROGRAM SELECTION 17 KEYPAD OR DISPLAY LOCKING 19 DECLARATION OF CONFORMITY EU 20 DECLARATION OF CONFORMITY UKCA 21 ...

Page 5: ...s of the instrument including the terminal SUPPLY to the weighed structure The cell cable must be individually led to its panel input and not share a conduit with other cables connect it directly to the instrument terminal strip without breaking its route with support terminal strips Use RC filters on the instrument driven solenoid valve and remote control switch coils Avoid inverters in the instr...

Page 6: ... WDESK LIGHT WDESK L WINOX L WTAB L semi alphanumeric backlit LCD six 20 mm digits 7 segments 46 signalling symbols WDESK R WINOX R WTAB R semi alphanumeric red LED six 20 mm digits 7 segments 16 indicator LEDs WINOX 2L semi alphanumeric backlit LCD six 40 mm digits 7 segments 46 signalling symbols Membrane keypad with buzzer W100 4 keys W200 5 keys WDESK LIGHT WDESK L R WINOX L R 2L 6 keys WTAB L...

Page 7: ...0 6 W standard DISPLAY RANGE 999999 NO OF DECIMALS 0 4 RELAY LOGIC OUTPUTS N 2 max 115 VAC 150 mA SERIAL PORTS RS485 RS232 BAUD RATE 2400 4800 9600 19200 38400 115200 HUMIDITY non condensing 85 STORAGE TEMPERATURE 30 C 80 C WORKING TEMPERATURE 20 C 60 C WDESK L R WINOX L R 2L WTAB L R POWER SUPPLY and CONSUMPTION VDC 12 24 VDC 10 6 W standard POWER SUPPLY and CONSUMPTION VAC 115 230 VAC 50 60 Hz 6...

Page 8: ...resistance on the two devices located at the ends of the network as described in the paragraph RS485 SERIAL CONNECTION E EC option if available selects 12 groups of 5 setpoint WDESK LIGHT 2 outputs settable setpoint TERMINALS LEGEND 1 12 2 13 3 14 4 15 5 16 6 17 OUTPUT No 1 7 RS232 TXD 18 OUTPUT No 2 8 RS232 RXD 19 OUTPUT COMMON 9 RS485 20 SUPPLY 12 24 VDC 10 RS485 21 SUPPLY 12 24 VDC RS232 RS485 ...

Page 9: ...strument inputs RXD 19 1 13 2 3 4 5 6 16 1415 1718 TXD 12 24 7 8 11 10 9 21 20 22 23 12 EC OPTION 3 2 1 7 6 8 5 4 10 11 9 8 E OPTION 1 3 2 4 5 6 7 14 11 9 10 13 12 16 15 16 2 16 2 to instrument OUT 1 OUT 2 OUT 3 OUT 4 OUT COMMON RS485 OUT 5 to OPT E EC RS232 SUPPLY SUPPLY Buttons not included in the supply N L 115 230 VAC 1 2 3 SUPPLY OUT SUPPLY OUT L N WARNING W200 WDOS 115 V 230 V OPTIONS INSTRU...

Page 10: ...ing a stiff wire on welding side TERMINALS LEGEND 1 SUPPLY 12 24 VDC 13 2 SUPPLY 12 24 VDC RS232 RS485 SHIELD GND E EC OPTION GND 14 3 RS232 TXD 15 OUTPUT No 5 4 RS232 RXD 16 E EC OPTION 5 OUTPUT No 1 17 RS485 6 OUTPUT No 2 18 RS485 7 OUTPUT No 3 19 8 OUTPUT No 4 20 9 OUTPUT COMMON 21 10 22 11 23 12 24 230 VAC 115 115 230 115 115 230 115 VAC ...

Page 11: ...y removing the six bottom screws and work on the welding side join the red points using a stiff wire 12 EC OPTION 3 2 1 7 6 8 5 4 10 11 9 8 E OPTION 1 3 2 4 5 6 7 14 11 9 10 13 12 16 15 4 to instrument Buttons not included in the supply 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 12 24 VDC supply RS485 OUT 5 to E EC OPT SUPPLY SUPPLY TXD RXD OUT 1 OUT 2 OUT 3 OUT 4 OUT COMMON RS...

Page 12: ...C OPTION 17 5 RS485 18 6 RS485 19 7 SUPPLY 12 24 VDC 115 230 VAC optional version OUTPUT 24 VDC 20 8 SUPPLY 12 24 VDC RS232 RS485 SHIELD GND E EC OPTION GND 115 230 VAC optional version OUTPUT 24 VDC RS232 RS485 SHIELD GND E EC OPTION GND 21 9 RS232 TXD 22 10 RS232 RXD 23 11 OUTPUT No 1 24 12 OUTPUT No 2 L PHASE 115 230 VAC optional ver 13 OUTPUT No 3 N NEUTRAL 115 230 VAC optional ver GROUND 115 ...

Page 13: ...2 blue 3 OUTPUT No 3 max 24 V 13 white 4 OUTPUT No 4 max 24 V 14 green 5 OUTPUT No 5 max 24 V 3 orange 6 OUTPUT COMMON max 24 V 15 purple 7 8 9 10 11 E EC OPTION 4 red 12 E EC OPTION GND 8 black 13 14 15 D4 Male RS232 serial port 1 2 RS232 RXD 10 yellow 3 RS232 TXD 9 blue 4 5 RS232 SHIELD GND 8 black 6 7 8 9 D5 Male RS485 serial port 1 2 3 4 RS485 6 yellow 5 RS485 SHIELD GND 8 black 6 RS485 5 blue...

Page 14: ...minal strip of the instrument close the RS485 termination jumpers on the furthest instrument if present otherwise connect a 120 ohm resistor on the terminal strip of the instrument RS232 SERIAL COMMUNICATION Instrument RS232 TX RS232 RX SUPPLY W100 W200 3 4 2 WDESK LIGHT 7 8 21 WDESK L R WINOX L R 2L WTAB L R 9 10 8 RS485 0 VDC SUPPLY 12 24 V RS485 RS232 0 VDC TX RX SUPPLY 12 24 V RS232 TX RX Tran...

Page 15: ...EY Short press Long press 3 s Into menus Power on Power off Cancel or return to previous menu Select figure to be modified or return to previous menu item Modify selected figure or go to next menu item Setting setpoint and hysteresis Confirm or enter in submenu Setting general parameters press MENU immediately followed by ESC The LEDs light up in sequence or in instruments with LCD display symbol ...

Page 16: ...s changes are applied right after pressing the ENTER key no further confirmation is required SETPOINT SYSTEM PARAMETERS WDESK LIGHT does not support E EC option just class 1 and just two setpoint are available MENU MENU ESC ...

Page 17: ...ation default enables weight receiving on selected port transmission rate 2400 4800 9600 19200 38400 115200 default 9600 no parity default even parity odd parity stop bit 1 2 default 1 SETTING THE NUMBER OF DECIMALS MENU ESC from 0 to 4 sets the number of decimals it MUST be equal to the number of decimals used by the transmitting instrument SETTING UNIT OF MEASURE MENU ESC default sets the unit o...

Page 18: ...ed when the weight is lower than the programmed setpoint value it opens when the weight is higher than or equal to the programmed setpoint value the contact will switch on the basis of gross weight the contact will switch on the basis of net weight If the net function is not active the contact will switch on the basis of gross weight TEST MENU ESC Outpu Test setting ensure that the corresponding o...

Page 19: ...ax full scale default 0 hysteresis value to be subtracted from the setpoint to obtain contact switching threshold for the decreasing weight For example with SET 100 and hysteresis 10 switching occurs at 90 for the decreasing weight ALARMS no serial port set as communication problems between transmitter and receiver check instrument electrical connections and settings maximum displayable value exce...

Page 20: ...uded The checksum value is obtained from the calculation of XOR exclusive or of the 8 bit ASCII codes of the characters considered This obtains a character expressed in hexadecimals with two digits that can have the values from 0 to 9 and from A to F ckck is the ASCII code of the two hexadecimal digits CR 1 character of string end 13 ASCII In case of negative weight the first character on the left...

Page 21: ...ng goes off to indicate that this item is now unlocked TEMPORARY MENU UNLOCKING MENU press and at the same time for 3 seconds you can now enter and modify all menus including the locked ones By returning to weight display the lock is restored DATA DELETION AND PROGRAM SELECTION WARNING operations must only be performed after contacting technical assistance After each operation the display shows pr...

Page 22: ...ry hardware code and serial number see section INSTRUMENT COMMISSIONING Set the active regulation on the instrument only if have not been set approved program according to EN45501 2015 and OIML R76 2006 for UE approved program according to NIST Handbook 44 NCWM PUB 14 for North America NTEP When a W series instrument is used in combination with an intelligent junction box or a weight transmitter t...

Page 23: ...on is also possible via the MODBUS and ASCII protocols no lock keypad lock if active when a key is pressed the message is displayed for 3 seconds keypad and display lock if active the kaypad is locked and the display shows the instrument model weight is not displayed by pressing a key the display shows for 3 seconds ...

Page 24: ...s déclarons avec cela responsabilité que le produit auquel se rapporte la présente déclaration est conforme aux normes citées ci après CZ Prohlášení o shode Tímto prohlašujeme že výrobek kterého se toto prohlášení týká je v souladu s níže uvedenými normami NL Conformiteit verklaring Wij verklaren hiermede dat het product waarop deze verklaring betrekking heeft met de hierna vermelde normen overeen...

Page 25: ... que le produit auquel se rapporte la présente déclaration est conforme aux normes citées ci après CZ Prohlášení o shode Tímto prohlašujeme že výrobek kterého se toto prohlášení týká je v souladu s níže uvedenými normami NL Conformiteit verklaring Wij verklaren hiermede dat het product waarop deze verklaring betrekking heeft met de hierna vermelde normen overeenstemt P Declaração de conformidade D...

Page 26: ......

Page 27: ......

Page 28: ...s product manuals are available online You can download the manuals in PDF format from www laumas com by consulting the Products section or the Download Area Registration is required Think about the environment before you print CERTIFICATION OF THE ENVIRONMENTAL MANAGEMENT SYSTEM in accordance with UNI EN ISO 14001 Laumas contributes to environmental protection by saving on paper consumption ...