KEW6305
8.8
●
Displayed items
<Screen 1, Upper row:
Target demand value
(W) >
It is set at “
Setting 15
”. Set the desired value.
<Screen 1, Middle row:
Predicted demand value
(W) >
Predicted values of average electrical power (demand values) which will be after the elapse of
demand measurement interval with present loads are displayed right after starting a measurement.
The predicted values are calculated successively when loads vary.
<Screen 1, Lower row & Screen 2, Lower row:
Present demand value
(W) >
This is the Present Demand Value(see definitions)
<Screen 2, Upper row:
Remaining time
>
This is the count down, in 1 sec. decrements to the end of the interval.
<Screen 2, Middle row:
Load factor
(%) >
This is the load factor(See definitions)
<Screen 3, Upper row & Middle row:
Date and time
>
These are the time and when the max. demand recorded so far from the start of the survey was
measured.
<Screen 3, Lower row:
Max. demand value
(W) >
The max. demand value measured between the beginning and the end of
measurement is displayed.