2DA/2DB-1
1-4-29
U110
Checking/clearing the drum count
Description
Displays the drum counts for checking, clearing the figure.
Purpose
To check the drum status. Also used to clear the count after replacing the durm during regular maintenance.
Since the count was cleared before shipping, do not clear it when installing. A drum count value less than
150K, however, cannot be cleared.
Method
1. Press the start key. The drum counter count is displayed.
2. Select the CLEAR using the up/down cursor keys. If the counter value is 150K or less, CLEAR is not dis-
played.
3. Press the start key. The count is cleared, and the screen for selecting a maintenance item No. is dis-
played.
Completion
To exit the maintenance mode without changing the count, press the stop/clear key. The screen for selecting a
maintenance item No. is displayed.
U130
Initial setting for the developer
Description
Replenishes toner to the developer unit to a certain level from the toner container that has been installed.
Purpose
To operate when installing the machine.
Method
1. Press the start key. The screen for executing is displayed.
2. Select the EXECUTE using the up/down cursor keys.
3. Press the start key. Installation of toner starts and time (minutes) is indicated until the installation ends.
4. When the installation is complete, FINISHED will be displayed if the installation is successful or NG will
be displayed if it has failed. If NG is displayed, check to see if the toner container contains toner and to
see if the toner container sensor malfunctions and then try again.
Completion
Press the stop/clear key after operation is complete. The screen for selecting a maintenance item No. is dis-
played.
U144
Setting toner loading operation
Description
Sets toner loading operation after completion of copying.
Purpose
To set whether or not toner is loaded on the drum after low density copying. Normally no change is necessary
from the initial setting.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Select either ON or OFF using the up/down cursor keys. The selected item is displayed in reverse.
Initial setting: OFF
2. Press the start key. The value is set.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
Maintenance
item No.
Description
Display
Description
ON
Toner loaded
OFF
Toner not loaded
Summary of Contents for KM-1650
Page 1: ...SERVICE MANUAL Published in June 05 2DA70763 Revision 3 KM 1650 2050 ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 248: ...2DA 2DB 1 2 3 2 Figure 2 3 2 Power source PCB silk screen diagram 220 240 V AC 120 V AC ...
Page 265: ...2DA 2DB 1 2 3 19 Figure 2 3 10 Operation unit PCB silk screen diagram ...
Page 280: ......