2DA/2DB
1-3-10
5. Close the DP, fit the fixing fitting from the
rear side of the right hinge, and secure it
with the two bronze TP screws M3 x 06.
6. Connect the cable of the DP to the MFP.
* Be sure to tighten the fixing screws on both
side of the connector.
Figure 1-3-13
7. Clean the pasting position for the caution
label with alcohol.
Paste the caution label that corresponds to
the language according to the destination to
the DP.
Figure 1-3-14
[Operation check]
1. Prepare an original on which 4 lines are
drawn 15 mm from the edges and the center
line is drawn.
2. Set the original on the DP and make a test
copy to check the copy image.
At this time, set the paper guide for the origi-
nal table and drawer to the paper size to be
used.
3. If the copy image does not match the origi-
nal image, carry out the following adjust-
ments in maintenance mode.
Maintenance mode 070 (sub-scan line
adjustment)
Maintenance mode 071 (leading edge tim-
ing adjustment)
Maintenance mode 072 (center line adjust-
ment)
Figure 1-3-15
Fixing fitting
Cable
Bronze TP screws M3 x 06
Caution label
15mm
15mm
15mm
15mm
Lines
Lines
Center line
Original