2DA/2DB-1
1-6-45
(2) Detaching and refitting the press roller
Follow the procedure below to replace the press roller.
Procedure
1. Remove the fixing unit (see page 1-6-43).
2. Remove the two screws and then separate
the fixing right unit and left unit.
Figure 1-6-80
3. Remove the three screws holding the press
roller guide from fixing right unit.
Figure 1-6-81
4. Remove the press roller from the fixing right
unit.
5. Replace the press roller and refit all the
removed parts.
Figure 1-6-82
Fixing left unit
Fixing right unit
Press roller guide
Fixing right unit
Press roller
Fixing right unit