2DA/2DB
2-1-11
(1) Formation of magnetic brush
The developing roller consists of a magnet roller with four poles and a sleeve roller. Rotation of the sleeve roller around
the magnet roller entrains toner, which in turn forms a magnetic brush at pole N1 on the magnet roller. The height of the
magnetic brush is regulated by the doctor blade; the developing result is affected by the position of the poles on the mag-
net roller and the position of the doctor blade.
A developing bias voltage generated by the high-voltage PCB (HVTPCB) is applied to the developing roller to provide
image contrast.
Figure 2-1-11 Forming a magnetic brush
Figure 2-1-12 Developing section block diagram
A
Doctor blade
Developing roller
A: Distance between the doctor blade and developing roller; 0.3 ± 0.05 mm
N1:870 x 10
-4
T
N2:400 x 10
-4
T
S1:725 x 10
-4
T
S2:910 x 10
-4
T
N1
94
86
100
S2
S1
N2
Drum
EPCB
YC22-5
YC8-10
YC3-14
DPCB
HVTPCB
YC4-2
TCDSW
DB
DB
TCS
OFS
YC1-8
TCS
TCDSW
OFS
Summary of Contents for KM-1650
Page 1: ...SERVICE MANUAL Published in June 05 2DA70763 Revision 3 KM 1650 2050 ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 248: ...2DA 2DB 1 2 3 2 Figure 2 3 2 Power source PCB silk screen diagram 220 240 V AC 120 V AC ...
Page 265: ...2DA 2DB 1 2 3 19 Figure 2 3 10 Operation unit PCB silk screen diagram ...
Page 280: ......