High voltage
U100
Checking the operation of main high voltage
132/60/50/10
U101
Setting high voltages
Developing bias
Transfer voltage
Separation voltage
27/45/22/45
166/177/37/35
1/35/42
U110
Checking/clearing the drum count
-
Developing
U130
Initial setting for the developer
-
U144
Setting toner loading operation
OFF
U157
Checking/clearing the developing drive time
-
U158
Checking the developing count
-
Fixing and
cleaning
U161
Setting the fixing control temperature
Primary stabilization fixing temperature
Secondary stabilization fixing temperature
Copying operation temperature 1
Copying operation temperature 2
Number of sheets for fixing control
Number of sheets for fixing control (thick paper)
140
160
170
180
5
20
U162
Stabilizing fixing forcibly
-
U163
Resetting the fixing problem data
-
U167
Checking/clearing fixing counts
-
U199
Checking the fixing temperature
-
Operation
panel and
support
equipment
U200
Turning all LEDs on
-
U202
Setting the KMAS host monitoring system
-
U203
Checking DP operation
-
U204
Setting the presence or absence of a key card or key counter
OFF
U207
Checking the operation panel keys
-
U233
Setting the ejection limit of the job separator
MODE0
U243
Checking the operation of the DP motors and solenoids
-
U244
Checking the DP switches
-
U245
Checking messages
-
U246
Setting the finisher
4/4/4
U249
Checking the paper ejection to optional devices
-
Mode setting
U250
Setting the maintenance cycle
150000
U251
Checking/clearing the maintenance count
-
U252
Setting the destination
Japan
U253
Switching between double and single counts
Double count
U254
Turning auto start function on/off
ON
U258
Switching copy operation at toner empty detection
Single mode
U260
Changing the copy count timing
After ejection
U264
Setting the display order of the date
Inch specifications:
MONTH-DATE-YEAR
Metric specifications:
DATE-MONTH-YEAR
U265
Setting OEM purchaser code
-
U277
Setting auto application change time
30
U326
Setting the black line cleaning indication
ON
U332
Setting the size conversion factor
1.0/1.0/1.0
U341
Specific paper feed location setting for printing function
-
U342
Setting the ejection restriction
ON
Section
Item
No.
Content of maintenance item
Initial
setting*
*Initial setting for executing maintenance item U020
Summary of Contents for KM-1650
Page 1: ...SERVICE MANUAL Published in June 05 2DA70763 Revision 3 KM 1650 2050 ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 248: ...2DA 2DB 1 2 3 2 Figure 2 3 2 Power source PCB silk screen diagram 220 240 V AC 120 V AC ...
Page 265: ...2DA 2DB 1 2 3 19 Figure 2 3 10 Operation unit PCB silk screen diagram ...
Page 280: ......