5.8 Alarm Terminal Block
Electrical parameters of the relay:
Max Switch Voltage: 250VAC/220VDC;
Max Switch Current: 2A
Max Switching Power: 60W
Dielectric Strength: 2KV
Note:
Pin 1 and pin 2 are normally-closed contacts; pin 2 and pin 3
are normally-open contacts. When the switch works properly,
pin 1 and pin 2 are open, pin 2 and pin 3 are closed; when an
alarm occurs, pin 1 and pin 2 are closed; pin 2 and pin 3 are open.
FAULT
3 2 1
Step 1: Remove the alarm terminal block from the switch.
Step 2: Secure the three wires for alarm into the alarm terminal block
in the required sequence.
Step 3: Insert the alarm terminal block into its socket.
ƽ
Wiring and Mounting
Figure 39 Alarm Terminal Block (socket)
The device provides an alarm terminal block on the rear panel for
alarm output. When the switch works properly, the normally-open
contacts of the alarm relay are closed and the normally-closed contacts
are open; when an alarm occurs, the normally-open contacts are
open and the normally-closed contacts are closed. The alarm is
outputted through a 3-pin 5.08mm-spacing plug-in terminal block.