Interface Module Installation
15
3.1.2 Inserting a 0.5U Interface Module into an Upper Slot
(Slot 2,Slot 4, or Slot 6)
Step 2:Push the mounting brackets into the slot completely. Insert
two captive screws (M2.5×6) into the screw holes of the switch to
secure the interface module to the switch.
1
Guide rail slot of the
interface module
Guide rail of the
interface module
Figure 14 Inserting a 0.5U Interface Module into an Upper Slot
Caution:
ƽ
To insert an interface module into an upper slot, keep the
"TOP" identifier on the module facing up.
ƽ
If the module cannot be pushed into place, do not force it,
because too much force may cause damage to the module.
In this case, remove the module and check the guide rail
slot for any foreign materials or deformation. If the fault cannot
be rectified, contact our sales or technical support personnel.
Step 1:Insert the guide rail of the interface module into the guide rail
slot with "TOP" facing up. Then push the module into the slot along
the guide rail slot until it is in position.
Summary of Contents for SICOM3000GPT