9. Empty hopper sensor
87
9.4 Machine box HLM
Cable sensor HLM
Cable power CAN HLM
Machinebox HLM
The hopper level management system ‘HLM’ has three components, the mini IO and two sensors. The mini IO is mounted on the right side of the
spreader close behind the PCB and has two connectors.
One connector is for the sensors and one for the signal which is connected to the EDW PCB
Colour cable
Position in
connector
function
1
1
CAN low
2
12
CAN high
3
11
ECU pwr
green/yellow
2
ECU gnd
Colour cable
Position in
connector
function
Brown
Left: 1
Right: 4
+ 12 V
Black
Left: 2
Right: 5
Signal
Blue
Left: 3
Right: 6
ground