4. Calibrations
4.2 Hopper calibration
(Pincode 5)
The Pin 5 calibration has to be done after adding additional weight to the machine. (Like a hopper extension)
Or if the weight offset to 0 is bigger than 25 kg.
After adding an extra options like an ‘hopper extension’ the empty hopper weight will changed. For this reason the weighing system must know the
new empty hopper weight.
The Pincode 5 calibration will only give access to 2 steps of the calibration process.
1.
The empty weight of the hopper
2.
The corresponding load cell value for an empty hopper
For a good and successful Pin 5 calibration please follow the steps below careful.
Step 1 Adjust the machine horizontal behind tractor.
Adjust the machine 100% horizontal on a flat (leveled) surface (in both directions) on the correct spreading height (75cm)
75 cm
47