4. Calibrations
4.1 Actuators calibration
After changing/repair an actuator or PCB or after memory error on the system, the actuators most be calibrated again.
For an good calibration process please follow the steps below:
Go to screen “hopper & act calibration
Select “CAL” button and press OK
The actuator should open and close (Emergency stop, press OK again)
Press the other “CAL” button for the other actuator
Values must be (after calibration) approximately between 15 and 1015
Calibrate all the 2 or 4 actuators (depending on machine configuration)
When calibrating is not possible or value’s are not close to the 15 and 1015 please check and measure the actuators
(see §2.6)
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
46