Powering Operations for the Commander III
3-6
Commander III Operation Manual
Powering Operations for the Commander III
This section describes how to power up and to power down the Commander III.
Powering up the system includes:
• Applying power to the entire system
• Starting the Control Circuit
Powering down the system includes:
• Shutting down the control power
• Removing power from the entire system
How to Power Up the Commander III
1.
Ensure factory air is applied to machine and main air supply is turned on.
2.
Check that all E-Stop buttons are out and safety gate door s are closed.
Note:
A pop-up is displayed on the user screen if an E-Stop is pressed. The pop-up
will indicate which E-Stop has been activated
3.
Make sure the electrical disconnect in the electrical cabinet is turned to the ON
position.
.
4.
Switch the green
CONTROL TRANS-
FORMER
switch to the ON position. It
should light up.
5.
Push the green
START MACHINE
button
to “boot up” the machine.
Note:
Boot up may take 2 to 3 minutes.
6.
All lights on the status light panel on the
electrical box should be illuminated.
“Description of the Six Light Panel” on
page 5-12
Note:
If a status light does not turn on during
the power up process, see the Trouble-
shooting Chapter in the Service Manual.
Summary of Contents for Commander III
Page 46: ...About Revisions 2 16 KVAL Manual ...
Page 81: ...Common Terms 2 51 KVAL Manual FIGURE 2 11 Example of a Validation Report ...
Page 162: ...Options KVAL Commander III Operation Manual 5 20 ...
Page 165: ......