Special Options (Calibrations)
KVAL Commander III Operation Manual
4-26
Special Options (Calibrations)
This section describes the calibrations of special options sometimes located on the machine.
Check your machine for these options before proceeding with the processes.
Thickness Feeler Option
Easy Check:
To verify if the machine has this option, check that the Thickness Feeler is located
on the back section or goto the manual screen and check if the Enable /Disable button is available.
If the machine does not have this option bypass this calibration.
See “Special Options (Calibrations)” on page 3-24, for calibration informations.
Important:
Setting the Door Feelers is the first calibration that should be checked or performed.
This calibration adjusts the encoders located in on Back Section These calibrations are a starting
reference for all calibrations.
See “Special Options (Calibrations)” on page 4-26 ,
for calibration informations.
Thickness Feeler Calibration
Important:
Setting the Door Feelers is the first calibration that should be checked or performed.
This calibration adjusts the encoders located in on Back Section These calibrations are a starting
reference for all calibrations.
Process to Calibrate Thickness Feelers
In this process, the encoder feedback in the
Diagnostic Screen
will be used to determine an aver-
age for the thickness of the door.
1.
Measure a know good door. The door should be true and possible. Capture the
Thickness Measurement
. (This measurement is used to compare to the thickness
captured by the feeler encoders.)
The
Thickness Feeler
is located on the back section
of the machine.