Special Options (Calibrations)
4-27
KVAL Commander III Operation Manual
2. Auto Feed
the door into the machine.
3.
Clamp the door.
4.
Unclamp the door
5.
Auto feed the door.
6.
Repeat
Auto Feed, Clamp, Unclamp
at least 5 times.
7.
Check the measurements fed back from the encoder. View the Diagnostic Screen.
8.
Get averages of the feedback.Write down the measurements.
9.
Enter the offsets from the averages and the measured door in the boxes under the
Door Width Feelers
and
Door Length Feelers
Menus.
10.
Enter a
negative offset
to move the
thickness adjust clamps closer.
11.
Enter a positive offset to move the
thickness adjust clamps further apart
.