F(v max)
11349 N
F(h normal)
4092 N
F(h max)
9242 N
M(k normal)
9703 Nm
M(k max)
18711 Nm
M(r normal)
5141 Nm
M(r max)
9806 Nm
Foundation loads for wall mounting position
F(v normal)
9329 N
F(v max)
10835 N
F(h normal)
2955 N
F(h max)
12215 N
M(k normal)
11841 Nm
M(k max)
18312 Nm
M(r normal)
4815 Nm
M(r max)
9806 Nm
Vertical force F(v), horizontal force F(h), tilting torque M(k), torque about
axis 1 M(r)
Fig. 4-44: Foundation loads
KR IONTEC
MA KR IONTEC V4 | Issued: 11.05.2021
www.kuka.com
| 85/344
Technical
data
Summary of Contents for IONTEC KR 20 R3100
Page 14: ...KR IONTEC 14 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Introduction...
Page 166: ...KR IONTEC 166 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Planning...
Page 188: ...KR IONTEC 188 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Start up and recommissioning...
Page 310: ...KR IONTEC 310 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Repair...
Page 340: ...KR IONTEC 340 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 KUKA Service...