11.5
Purge option D
Description
The functional principle of compressed air preparation system PURGE op-
tion D corresponds to that of PURGE option B. It is additionally equipped
with a holder for installation on the base frame. The option consists of a
pressure regulator unit that limits the operating pressure of the system
and compensates for pressure fluctuations.
The compressed air preparation system is not suitable for installation in a
hygiene area.
Fig. 11-11: PURGE option D
Basic data
Designation
Article number
Weight
PURGE Option D
0000-363-927
approx.
2.4 kg
Further information about the ambient conditions is contained in the as-
sembly instructions for the robot and robot controller.
Operating pressure
(PURGE)
max. 0.03 MPa (0.3 bar) ±10%
Air consumption
0.1 m
3
/h
Air line connection
Push-in fitting for hose, 6 mm
Input pressure
0.1 - 1.2 MPa (1 - 12 bar)
Pressure regulator
0.005 - 0.07 MPa (0.05 - 0.7 bar)
Manometer range
0.0 - 0.1 MPa (0.0 - 1.0 bar)
Start-up and recommissioning
(
>>>
11.5.1 "Starting up PURGE option D" Page 332
)
Maintenance
If used for its intended purpose, the option requires minimal maintenance,
i.e. visual inspections are recommended. In certain operating conditions,
KR IONTEC
MA KR IONTEC V4 | Issued: 11.05.2021
www.kuka.com
| 331/344
Options
Summary of Contents for IONTEC KR 20 R3100
Page 14: ...KR IONTEC 14 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Introduction...
Page 166: ...KR IONTEC 166 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Planning...
Page 188: ...KR IONTEC 188 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Start up and recommissioning...
Page 310: ...KR IONTEC 310 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Repair...
Page 340: ...KR IONTEC 340 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 KUKA Service...