Alarm messages and possible causes
95
5
5.2.2
Resolving problems with the flow factor regulation (only AXIS W)
Under certain conditions, the display of the flow factor can freeze despite having
carried out the
weigh quantity
function. The following alarm message appears
in the display.
Figure 5.2:
Flow factor error message
Acknowledging an alarm message:
1.
Proceed as described in chapter
5.2.1: Acknowledging an alarm message,
page 94
.
2.
Switch the control unit Quantron E2 off (
ON/OFF
) and then restart it.
3.
Switch to the
weigh
quantity
menu using the
kg key
.
4.
Select the function
new fertiliser
.
5.
Press the
enter key
The flow factor is set to 1.0 and the remaining fertiliser quantity in the
hopper is weighed.
6.
Press the
ESC key
to return to the
previous menu
or
Press the
menu key
to return to the
operating screen
.
7.
Switch to the
operating screen
.
The weighed quantity appears on the display field.
The error is cleared and the spreading process can continue.
A new flow factor regulation is carried out.
n
CAUTION
Possible spreading error
This alarm message can lead to spreading errors which have a
negative impact on the environment.
immediately stop
the spreading process.