![KUHL Quantron E2 Original Instructions Manual Download Page 34](http://html.mh-extra.com/html/kuhl/quantron-e2/quantron-e2_original-instructions-manual_2009377034.webp)
Operation of the Quantron E2
4
28
4.2.4
Weigh quantity
In this menu, you can weigh the fertiliser quantity contained in the hopper and set
the parameters for controlling the flow factor.
Figure 4.6:
Weigh quantity menu
[1]
Display of spreader's forward speed
[2]
Weighed quantity in the hopper
[3]
Filling options
[4]
Weigh remnant (only displayed for the operating mode
Auto km/h + Stat. kg
)
[5]
Quit
The menu shows the
remaining fertiliser quantity
. This volume depends on the
following values:
Menu item
weigh quantity
Menu item
machine tare
NOTICE
The function
weigh quantity
can only be carried out if the machine is at a stand-
still and in a horizontal position.
NOTICE
The function
weigh quantity
is only effective if the system is using either the
Auto km/h + Auto kg
or
Auto km/h + Stat. kg
operating modes.
For the control unit supplied with the AXIS W fertiliser spreader, the
Auto km/h
+ Auto kg
operating mode is preset as standard at the factory.