Operation of the spreader
Brine equipment
Filling
Close stop valve next to the large debris filter.
The vehicle must not be moved while the filling hose is attached. Park vehicle at the place
of filling and remove ignition key
.
Connect limit switch cable of teh filling equipment.
Connect filling hose via C-connection withthe spreader.
Open stop valve of the filling equipment.
Start filling.
Limit switching
The limit switch is mounted at the factory in the highest position. This way
the solid and brine chambers are emptied evenly when spreading with the FS30.
If only sections of the road are spread with damp salt, the brine tanks can only
be filled partially.
In this case the limit switch can be attached at a lower postion at the tank.
The arrow at the hexagon must show upwards.
The upper borehole is to be closed with a sealing plug.
Close stop valve at filler tube.
Remove filling hose and screw the sealing cover on the filler tube.
Unplug the limit switching cable and screw sealing cover on the installation box.
Open the stop valve next to the large debris filter for the operation of the spreader again.
If the limit switching is not used for filling, the brine tanks can overflow. In this case the
unneccessary brine is drained off via an overflow hose at the back of the vehicle.
Subject to changes
English
Summary of Contents for DUPLEX
Page 2: ...2 English ...
Page 7: ...Chapter 01 7 www kugelmann com CHAPTER 01 Important Instructions Subject to changes English ...
Page 19: ...Chapter 03 19 www kugelmann com Chapter 03 Technical data equipment English ...
Page 33: ...English Chapter 04 33 www kugelmann com Subject to changes ...
Page 37: ...Chapter 05 37 www kugelmann com CHAPTER 05 Operating the spreader Subject to changes English ...
Page 59: ......