PERIODIC SERVICE
46
B
Checking Transmission Fluid Level
To avoid personal injury:
A
Allow the transmission case to cool down
sufficiently when cleaning its surface.
1. Park the machine on a flat surface, lower the
implement to the ground and shut off the engine and
remove the key.
Allow the machine to idle for 1-3 minutes, and then
check fluid.
2. Raise and lock the operator's seat.
3. To check the oil level, draw out the dipstick, wipe it
clean, replace it, and draw it out again. Check to see
that the oil level lies between the two notches.
If the level is too low, add the new oil to the prescribed
level at the oil inlet.
(See "LUBRICANTS AND FUEL" in "MAINTENANCE"
section.)
A
If oil level is low, do not run engine.
Add the new oil to the prescribed level at the oil inlet.
B
Lubricating All Grease Fittings
To avoid personal injury:
A
Be sure to stop the engine and remove the key
before greasing.
Grease the following location.
B
Checking Movable Parts
If any of the movable parts, such as levers and pedals, is
not smoothly moved because of rust or anything sticky, do
not attempt to force it into motion.
In the above case, remove the rust or the sticky thing, and
apply oil or grease on the relevant spot.
Otherwise, the machine may get damaged.
(1) Oil level dipstick
(2) Oil plug and breather cup
(A) Oil level is acceptable
within this range.
(1) Mower universal joint
(1) Spindle shaft
(2) Belt tension pulley
(3) Belt tension pivot
(4) Anti-scalp roller (Grease the bosses.)
Summary of Contents for ZG222A-AU
Page 13: ...SAFE OPERATION 6 7 DANGER WARNING AND CAUTION LABELS ...
Page 14: ... 7 SAFE OPERATION ...
Page 15: ...SAFE OPERATION 8 ...
Page 16: ... 9 SAFE OPERATION ...
Page 19: ...SERVICING OF MACHINE 2 1 ROPS serial No ...
Page 53: ...MAINTENANCE 36 PERIODIC SERVICE CHART LABEL 1 Part No K3277 6551 ENGLISH ...