Cleaning and Changing Air Cleaner Element
A
Change air cleaner element (1) once a year or six times of
cleaning.
(Cleaning Air Filter Element)
A
When dry dust adheres
1. To clean the element, use clean dry compressed air on the
inside of the element.
Air pressure at the nozzle must not exceed 205 kPa (2.1
, 30 psi).
Maintain reasonable distance between the nozzle and the
filter.
Cleaning Fuel Filter
1. Empty the fuel tank and disconnect the fuel pipe.
2. Loosen the ring nut and take out the filter (1).
3. Wash the filter clean off impurities with fresh fuel.
4. Take much care when handling the element because it is very
fragile.
A
If the element should have holes, replace it with a new
one. A damaged element will shorten the service life of
the nozzle and injection pump.
[4] CHECK POINT OF EVERY 500 HOURS
Changing Fuel Filter
1. Empty the fuel tank and disconnect the fuel pipe.
2. Loosen the ring nut and take out the filter (1).
3. Replace the filter (1).
4. Take much care when handling the element because it is very
fragile.
A
A damaged element will shorten the service life of the
nozzle and injection pump.
(1)
Element
0000009368E
(1)
Filter
0000009677E
(1)
Filter
0000009370E