![Kubota SSV65 Operator'S Manual Download Page 63](http://html1.mh-extra.com/html/kubota/ssv65/ssv65_operators-manual_2008909063.webp)
37
OPERATION OF THE MACHINE
ATTACHMENT CONTROL DEVICE
(OPTION)
This option is used to feed electrical power for an
attachment (to drive a valve, for instance).
With the AUX port ready for use, power can be supplied.
K: +12V and B: GND of the 14-pin coupler attached on the
arm (see below)
A
The K (+12V) of the 14-pin coupler turns on when the
starter switch is in "RUN" position.
C
Operation
Press the numbered electrical control switch on the left or
right lever that corresponds with the desired valve
function, to be powered at +12V
C
14-pin coupler harness connection chart
REF. No. means the same number of switches of next
figure.
A
AUX 3rd func. is momentaly action.
A
AUX electrical mode change is alternate action.
(1) 14-pin coupler
REF.
No.
Pin
Port
REMARKS
-
B
GND
1
C
AUX 1st func.
2
D
AUX 1st func.
3
E
AUX 2nd func.
4
F
AUX 2nd func.
5
G
AUX 3rd func.
6
H
AUX 3rd func.
7
J
AUX electrical mode change
-
K
+12 V