OPERATION AND INSTALLATION MANUAL
COD. 091003 - KME 18-22-30-37 - REV. 07 - DATA 11/2016
pag.42 of 68
7.2
ALARMS LIST
TYPE OF ALARM
DESCRIPTION
"ALLARME NTC > "
"NTC alarm"
Temperature probe failure
"ALTA T. OLIO"
"OIL HIGH TEMP.AL"
T. MAX setting exceeded
"BASSA T. OLIO"
"OIL LOW TEMP."
T. MIN setting exceeded
"TERMICO COMPRES."
"MOTOR TH. SWITCH "
Main motor thermal relay setting exceeded
"TERMICO VENTIL."
"FUN TH. SWITCH AL"
Electric fan thermal relay setting exceeded
"ALLARME TRASDUT."
"PRESSURE TRD AL."
Transducer failure
"EMERGENZA ATTIVA"
"Emergency SWITCH"
Mushroom head emergency stop button
pressed
"ANOMALIA FASI "
"AC. Phase ERROR "
Phase sequence inverted
"ALLARME SISTEMA!"
"SISTEM ALARM !!!"
General alarm