CONFIDENTIAL - This document is the property of K.T.C. S.r.l. and cannot be reproduced or issued to third parties without written
authorization. K.T.C. shall safeguard its rights to the full extent of the law.
OPERATION AND INSTALLATION MANUAL
COD. 091003 - KME 18-22-30-37 - REV. 07 - DATA 11/2016
pag.53 of 68
8.1.2
USING AN OPTIKRIK TENSION GAUGE
Figura 13
Figure 14
Figure 15
1-
Figure 13 (A, B or C) shows the three correct ways to grip the gauge so that the pressure is applied only on the
pressure pad
.
2-Reset the
indicator arm
by lowering it completely as indicated in figure 14.
3-Position the tension gauge on the taut side of the belt, with the part resting of the
indicator arm
set
at the mid-point between the pulleys, as indicated in figure 15.
Check gauge alignment ensuring that it is parallel with the belt branch.
4-Press slowly on the
pressure pad
.
When you hear a “click”, immediately stop and remove the tension gauge; this must be done very
carefully to prevent compromising the measurement reading taken by the
indicator arm
.
5-Read the tension on the indicator arm as shown in figure 13.