10 Related Documents
107 of 116
CHTRa
10.2.3 Tightening torques
Prerequisites
1.
The threads of the screw/bolt and nut are not damaged.
2.
The threads and bearing surfaces of the screws/bolts and nuts are level, and have
been deburred and cleaned thoroughly.
3.
The threads move smoothly.
4.
The washers are level, and have been deburred and cleaned thoroughly.
Pump
Observe the tightening torques for the screwed/bolted connections as per relevant
work instructions. (
ð
Section , Page 000)
Table 27:
Tightening torques for pump feet fastening studs
Thread
Non-drive end
Drive end
M20
47
224
M24
68
346
M27
108
529
M30
163
630
M36
217
1071
M42
318
1891
Flange connection
The tightening torques specified here apply to flange connection bolts which are
included in KSB’s scope of supply.
Foundation bolts or special
foundation bolts
Refer to the installation plan for the foundation bolt or special foundation bolt
tightening torques.
Bolts for flange connection
(suction nozzle, discharge
nozzle and tapping nozzle)
The tightening torques are only valid for bolts and screws included in KSB’s scope.
Table 28:
Tightening torques for flanges to EN 1092, PN 100
DN
Thread
[Nm]
15
M12
85
80
M24
420
150
M30
1375
Related documents