25
Using solenoid comfort operation
The feeder wagon is equipped with solenoid valves.
Set the hydraulic control unit of the tractor to “pressure”
(oil in circulation) and secure the control lever in this
position.
The required hydraulic function is carried
out by operating the corresponding electrical
switch.
The pick-up can be operated independently of the other
functions. The other cylinder functions (articulated
drawbar, tailgate, etc.) can be operated independently
of the floor conveyor and pick-up function.
However, after the function has been carried out, the
electrical switch for these cylinder functions must be
returned to neutral position.
During on-road driving it is advisable to switch the
tractor hydraulics off, to avoid unnecessary oil
circulation and warming.
For more detail see “Practical application for loading /
unloading”.
(1) “On” – “off” switch for electrical supply
(2) Indicator lamp (green) lights up when (1) is
switched on.
(3) Switch for floor conveyor operation: forward - off -
reverse. Switch in top position: reverse movement.
Use this switch to switch off the moving floor.
(4) Switch for operation of pick-up
(5) Switch for operation of articulated drawbar
(6) Switch for operation of hydraulic rear panel und
der Schaltung der Dosierwalzen
(7) Switch for operation of hydraulic collapsible box
(on request for D types)
(8) Switch for operation of hydraulic blade 0-switching
(for D types on request)
(9) Indicator lamp (red) lights up when blade
0-switching is operated or blade safety device
actuates.
(10) Cross conveyor belt - RH or LH rotation. Central
positon: cross conveyor belt is switched off.
(11) Turning knob for stepless moving floor adjustment
from min. to max. In the minimum position the
moving floor is running at extremely low speed.
Therefore always use switch (3) to switch off the
moving floor.
(12) Indicator lamp (greed) lights up when the rear gate
is fully opened.
(13) Indicator lamp (red) lights up when floor conveyor
is switched on using switch (3). Lamp goes out
when automatic floor conveyor shut-down has
occurred, i.e. the wagon is full.
(14) “On” – “off” switch for electrical supply
(15) Indicator lamp (green) lights up when (1) is
switched on.
(16) Moving floor operation: floor - off - reverse. Switch
in top position: reverse movement
(17) Switch for stepless moving floor speed adjustment
(18) Hydraulic rear gate operation and control of
metering rollers.
(19) Cross conveyor belt - RH or LH rotation. Central
position: cross conveyor belt is switeched off.
(20) Emergenca cut-out
(21) Switch activating the scraper floor rapid motion.
Must only be used at the last stage of the
unloading process.
The rapid motion valve will
increase the scraper floor speed depending on the
oil throughput made available by the tractor. At the
end of the unloading process, the rapid motion
valve must be switched off again.
Front control box
Rear control box (optional)
10
7
5
4
21
8
6
11
9
12
13
Summary of Contents for TITAN 6/36 D
Page 9: ...9 ...
Page 56: ...56 Hydraulic circuit diagram with comfort operation with Conveyor belt ...
Page 57: ...57 Hydraulic circuit diagram with comfort operation without Conveyor belt ...
Page 62: ...62 ...
Page 63: ...63 ...