3.5.3 Installation requirements for concrete roofs
CAUTION!
Follow these recommendations to make sure that the instrument measures correctly.
Figure 3-17:
Installation on a concrete roof
1
The diameter, d, of the hole must be greater than the thickness, t, of the concrete.
2
If the thickness, t, of the concrete is greater than the diameter, d, of the hole, install the instrument in a recess.
d
t
1
2