TECHNICAL DATA
9
141
OPTIFLEX 1300 C
www.krohne.com
01/2008 • 4000172301 - HB OPTIFLEX 1300 R02 en
9.2 Pressure/temperature table for probe selection
Ensure that the transmitters are used within their operating limits. Observe the following
requirements.
Figure 9-1:
Pressure/temperature table for probe selection
1
Process pressure, P
s
[bar]
2
Flange temperature, T [
°
C]
3
High-pressure (HP) version of the Ø2 mm single cable probe
4
Double rod, double cable, single rod, Ø4 mm single cable and coaxial probes
5
Ø8 mm single cable probe
6
Standard version of the Ø2 mm single cable probe
Figure 9-2:
Pressure/temperature table for probe selection
1
Process pressure, P
s
[psi]
2
Flange temperature, T [
°
F]
3
High-pressure (HP) version of the Ø0.08" single cable probe
4
Double rod, double cable, single rod, Ø0.15" single cable and coaxial probes
5
Ø0.3" single cable probe
6
Standard version of the Ø0.08" single cable probe
HB_OPTIFLEX1300_EN_D4_080428.book Page 141 Tuesday, April 29, 2008 2:47 PM