INSTALLATION
3
19
OPTIFLEX 1300 C
www.krohne.com
01/2008 • 4000172301 - HB OPTIFLEX 1300 R02 en
3.2.3 How to assemble the remote housing
•
Attach the wall bracket to the flexible conduit.
•
Tighten the locking nut
2
with a 24 mm wrench.
•
Attach the wall bracket to a wall or pipe (DN50...100 / 2"...4").
•
Loosen the housing locking screw
4
with a 5 mm Allen wrench.
•
Remove the housing.
Figure 3-6:
Part 1 of assembly procedure
1
2
3
4
5
HB_OPTIFLEX1300_EN_D4_080428.book Page 19 Tuesday, April 29, 2008 2:47 PM