8
TECHNICAL DATA
122
IFC 300
www.krohne.com
06/2009 - 4000069802 - MA IFC 300 R03 en
Display and user interface
Display and user interface
Display and user interface
Display and user interface
Graphic display
LC display, backlit white.
Size: 128 x 64 Pixel, corresponds to 59 x 31 mm = 2.32" x 1.22"
Display can be turned in steps of 90
°
.
Ambient temperatures below -25
°
C / -13
°
F, may affect the readability of the display.
Operating elements
4 optical keys for operator control of the signal converter without opening the
housing.
Infrared interface for reading and writing all parameters with IR interface (option)
without opening the housing.
Remote control
PACTware
®
(incl. Device Type Manager (DTM))
HART
®
Hand Held Communicator from Emerson Process
AMS
®
from Emerson Process
PDM
®
from Siemens
All DTMs and drivers are available free of charge from the manufacturer's website.
Display functions
Display functions
Display functions
Display functions
Operating menu
Setting the parameters using 2 measured value pages, 1 status page, 1 graphics
page (measured values and graphics are freely adjustable)
Language display texts (as
language package)
Standard: English, French, German, Dutch, Portuguese, Swedish, Spanish, Italian
Eastern Europe: English, Slovenian, Czech, Hungarian
Northern Europe: English, Danish, Polish
China: English, Chinese
Russia: English, Russian
Units
Metric, British and US units selectable as required from lists for volume / mass flow
and counting, flow velocity, electrical conductivity, temperature, pressure
Measuring accuracy
Reference conditions
Medium: water
Temperature: 20
°
C / 68
°
F
Pressure: 1 bar / 14.5 psi
Inlet run:
≥
5 DN
Maximum measuring error
±
0.15% of the measured value
±
1 mm/s, depending on the measuring sensor
For detailed information and accuracy curves, see chapter "Accuracy".
Repeatability
±
0.06% to OIML R117; not valid for WATERFLUX 3000
.book Page 122 Wednesday, June 10, 2009 4:20 PM