8
TECHNICAL DATA
130
IFC 300
www.krohne.com
06/2009 - 4000069802 - MA IFC 300 R03 en
Current input
Current input
Current input
Current input
Function
The following values can be delivered from the measuring sensor to the current
input: temperature, pressure and current
Operating data
Basic I/Os
Basic I/Os
Basic I/Os
Basic I/Os
Modular I/Os
Modular I/Os
Modular I/Os
Modular I/Os
Ex i
Ex i
Ex i
Ex i
Active
-
U
int, nom
= 24 VDC
I
≤
22 mA
I
max
≤
26 mA
(electronically limited)
U
0, min
= 19 V
at I
≤
22 mA
No HART
®
U
int, nom
= 20 VDC
I
≤
22 mA
U
0, min
= 14 V at I
≤
22 mA
No HART
®
U
0
= 24.5 V
I
0
= 99 mA
P
0
= 0.6 W
C
0
= 75 nF / L
0
= 0.5 mH
No HART
®
Passive
-
U
ext
≤
32 VDC
I
≤
22 mA
I
max
≤
26 mA
(electronically limited)
U
0, max
= 5 V
at I
≤
22 mA
No HART
®
U
ext
≤
32 VDC
I
≤
22 mA
U
0, max
= 4 V at I
≤
22 mA
No HART
®
U
I
= 30 V
I
I
= 100 mA
P
I
= 1 W
C
I
= 10 nF
L
I
=0 mH
No HART
®
.book Page 130 Wednesday, June 10, 2009 4:20 PM