Residual risk
A risk analysis in accordance with the pressure equipment directive has been carried out for the
devices . The residual risk is described as follows:
•
The devices are designed according to the valid and applicable rules and standards for static
operation and their pressure resistance is calculated for the declared maximum pressure
and temperature (no calculation for cyclical change).
•
Responsibility for the use of the measuring devices with regard to corrosion resistance of the
used materials against the measured fluid lies solely with the operator.
•
Avoid abrasion.
•
Avoid pulsation and cavitation.
•
Protect devices from vibration and high-frequency oscillation.
•
Draining (backflow) may be delayed due to the float in the measuring tube.
•
Implement appropriate measures to counteract external fire hazards