8
TECHNICAL DATA
96
H250 M40
www.krohne.com
03/2020 - 4000640706 - MA H250-M40 R06 en
8.4.5 H250U - Vertical installation position
Flow direction: vertical downwards
EN
ASME
Cone
Water [l/h]
Air [Nm
3
/h]
Pressure loss
[mbar]
DN15
1/2"
K 15.1
65
1.6
175
K 15.2
110
2.5
178
K 15.3
170
4
180
K 15.4
260
6
200
K 15.5
420
10
220
K 15.6
650
16
290
K 15.7
1100
28
520
K 15.8
1500
40
840
DN25
1"
K 25.1
1150
30
97
K 25.2
1800
45
85
K 25.3
2700
70
92
K 25.4
4500
120
115
K 25.5
7600
200
172
DN50
2"
K 55.1
9000
240
220
K 55.2
15000
400
230
K 55.3
21000
550
240
Table 8-25: H250U - Vertical installation position, metric
EN
ASME
Cone
Water [GPH]
Air [SCFM]
Pressure loss
[psig]
DN15
1/2"
K 15.1
17.2
0.99
2.57
K 15.2
29.1
1.55
2.62
K 15.3
44.9
2.48
2.65
K 15.4
68.7
3.72
2.94
K 15.5
111
6.20
3.23
K 15.6
172
9.92
4.26
K 15.7
291
17.4
7.64
K 15.8
396
24.8
12.3
DN25
1"
K 25.1
304
18.6
1.42
K 25.2
476
27.9
1.25
K 25.3
713
43.4
1.35
K 25.4
1189
74.4
1.69
K 25.5
2008
124
2.53
DN50
2"
K 55.1
2378
149
3.23
K 55.2
3963
248
3.38
K 55.3
5548
341
3.53
Table 8-26: H250U - Vertical installation position, imperial