1
SAFETY INSTRUCTIONS
6
H250 M40
www.krohne.com
03/2020 - 4000640706 - MA H250-M40 R06 en
1.1 Software history
The electronic revision (sticker on the base module ESK4 / ESK4A) indicates the respective
hardware/software status of the electronics.
All add-on modules (ESK4-T, ESK4-FF and ESK4-PA) have an additional sticker indicating their
respective firmware version.
Electronic revision
Explanations
ER 1.1.x
Basic version (cannot be combined with other indicator versions):
ESK4 / current output 4
…
20 mA with HART
®
communication
ESK4 HART DD 01.01.
ESK4 HART DTM 01.03.
ER 2.0.x
Functional add-on to ER 1.1.x:
can be combined with indicator version ESK4 FF / Foundation Fieldbus
(Firmware version FF module from 1.0.2)
ER 2.1.x
Functional add-on to ER 2.0.x:
can be combined with indicator version ESK4-PA / Profibus PA
(Firmware version PA module from 1.0.0)
can be combined with indicator version ESK4-IO / LCD, binary inputs/outputs
(Firmware version IO module from 1.1.0)
ER 2.2.x
Functional add-on to ER 2.1.x:
Support of failure signal (low) according to NE 43
for the ESK4 current output module
ER 3.0.x
Functional add-on:
Update for HART
®
communication from 5.9 to 7.4 including new DD/DTM
ESK4A HART DD 01.01
ESK4A HART DTM 01.04
(Extension of module designation from ESK4 to ESK4A for HART
®
7)
can be combined with ESK4-FF (Firmware version FF module from 1.0.2)
ESK4-PA (... PA module from 1.0.0)
ESK4-IO (... IO module from 1.2.0)
ER 3.1.x
Functional add-on:
Support of application diagnostics for ESK4A/HART (e.g. blocked float or pulsating float)
can be combined with ESK4-IO (Firmware version IO-module from 1.3.0)
Table 1-1: Electronic revision