INSTALLATION
22
H250 M40
www.krohne.com
03/2020 - 4000640706 - MA H250-M40 R06 en
Minimum distance between devices
When several devices are installed next to each other, a minimum distance of > 300 mm / 11.8"
between the devices is necessary.
Take special note of the installation position for the H250H with horizontal flow
direction:
In order to comply with thermal parameters and measuring accuracy, H250H flowmeters for
horizontal installation are to be installed in the pipeline so that the display is located on the side
of the measuring tube. The maximum product and ambient temperatures indicated as well as
the measuring accuracy are based on lateral installation of the indicator.
Figure 3-1: Minimum distance between devices
Figure 3-2: Installation position for H250H