Kramer Electronics Ltd.
TP-594Txr, TP-594Rxr
– Connecting the TP-594Txr
9
4. Control the smart TV via IR:
▪
On
TP-594Txr
connect an IR sensor cable to the IR 3.5mm mini jack
.
▪
On
TP-594Rxr
connect the IR 3.5mm mini jack
to an emitter cable and attach the
emitter side to the IR sensor of the smart TV.
▪
Point the smart TV IR remote controller to the IR sensor to pass an IR command via
HDBT to the smart TV.
5. Control the smart TV via RS-232:
▪
On
TP-594Txr
connect a room controller (for example, the Kramer
SL-240C
with
Kramer Control) to the RS-232 3-pin terminal block connector
.
▪
On
TP-594Rxr
connect the RS-232 3-pin terminal block connector
to the smart
TV.
▪
Send RS-232 commands via the room controller to the smart TV.
6. Control the blinds:
▪
On
TP-594Txr
connect a controller (for example,
SL-240C
room controller) to the
ETHERNET RJ-45 port
.
▪
On
TP-594Rxr
connect the ETHERNET RJ-45 port
to a relay control gateway
(for example, the Kramer
FC-7
).
▪
On
FC-7
connect the relay to the blinds in the room.
▪
Send open/close commands from
SL-240C
to
FC-7
to the blinds via the Ethernet.
7. Output the smart TV audio via TOSLINK connections to the AV receiver:
▪
On
TP-594Rxr
connect the smart TV acceptor to the TOSLINK IN connector
.
▪
On
TP-594Txr
connect the TOSLINK OUT connector
to the AV receiver source
and connect the AV receiver source to active speakers.
describes in detail how to connect and set the audio ports.
Connecting the Analog Audio Output to a
Balanced/Unbalanced Stereo Audio Acceptor
The following are the pinouts for connecting the analog audio output to a balanced or
unbalanced stereo audio acceptor:
Figure 4: Connecting to a Balanced Stereo Audio
Acceptor
Figure 5: Connecting to an Unbalanced Stereo Audio
Acceptor
6
23
7
24
13
23
26
9