![Korenix JetNet 4706 User Manual Download Page 76](http://html1.mh-extra.com/html/korenix/jetnet-4706/jetnet-4706_user-manual_1997849076.webp)
JetNet 4706/4706f Industrial Managed PoE Switch
72
4.9.4
CLI Commands for SNMP
Command Lines for SNMP configuration
Feature
Command Line
SNMP Community
Read Only Community Switch(config)# snmp-server community public ro
community string add ok
Read Write Community Switch(config)# snmp-server community private rw
community string add ok
SNMP Trap
Enable Trap
Switch(config)# snmp-server enable trap
Set SNMP trap enable ok.
SNMP Trap Server IP
without specific
community name
Switch(config)# snmp-server host 192.168.10.33
SNMP trap host add OK.
SNMP Trap Server IP
with version 1 and
community
Switch(config)# snmp-server host 192.168.10.33 version 1
private
SNMP trap host add OK.
Note: private is the community name, version 1 is the
SNMP version
SNMP Trap Server IP
with version 2 and
community
Switch(config)# snmp-server host 192.168.10.33 version 2
private
SNMP trap host add OK.
Disable SNMP Trap
Switch(config)# no snmp-server enable trap
Set SNMP trap disable ok.
Display
Switch# sh snmp-server trap
SNMP trap: Enabled
SNMP trap community: public
Switch# show running-config
.......
snmp-server community public ro
snmp-server community private rw
snmp-server enable trap
snmp-server host 192.168.10.33 version 2 admin
snmp-server host 192.168.10.33 version 1 admin
……..