JetNet 4706/4706f Industrial Managed PoE Switch
39
you need to activate the flow control function of the remote network device in order to let the flow
control of that corresponding port on the switch work. “Disable” means that you do not need to
activate the flow control function of the remote network device, as the flow control of that
corresponding port on the switch will work either way.
Once you have finished configuring the settings, click the
Apply
button to save the configuration.
Technical Tips:
If both ends are going at different speeds, they will not link to each other. If both
ends are in different duplex modes, they will be connected by half mode.
4.3.2 Port
Status
Port Status shows you the current port status.
A description of each column is as follows:
Port
: Port interface number.
Type
: 100BASE -> Fast Ethernet port.
Link
: Link status. Up -> Link UP. Down -> Link Down.
State
: Enable -> State is enabled. Disable -> The port is disabled by user configured.
Speed/Duplex
: Current working status of the port.
Flow Control
: The state of the flow control.
4.3.3 Rate
Control
Rate control is a form of flow control used to enforce a strict bandwidth limit of a port. You can
program separate trasmitting (Egress Rule) and receiving (Ingress Rule) rate limits for each port,
and even apply the limit to certain packet types as described below.