Hold Time (Sec):
Waiting time to ping the target device for the duration of
remote device boot
How to configure: After selecting Ping Failure event type, the system will
turn Relay Output to short state and continuously ping the target device.
When the ping failure occurred, the switch will turn the Relay Output to
open state for a period of Reset Time.
After the Reset Time timeout, the system will turn the Relay Output to close
state. After the Hold Time timer is timeout, the switch system will start ping
the target device.
Ex: Reset Time is 5 sec, Hold Time is 50 sec.
If the ping failure occurred, the switch system will turn Relay output to open
state to emulate power switch off for 5 sec periods. After Reset Time
timeout, the Switch system will start ping target device after 50 sec periods.
The period time is for target device system booting. During the period, the
switch system will not ping target device until Hold Time is timeout.
Event Type:
Super Ring Failure
Select Super Ring Failure. When the Rapid Super Ring topology is
changed, the system will short Relay Out and lengthen DO LED.