• Keep part of your body in contact with the metal chassis to dissipate the static
charge while handling the processor.
• Avoid moving around unnecessarily.
• Use a ground strap attached to the front panel (with the bezel removed.)
To remove a DIMM from a T5000PAL server board slot, follow these steps:
1. Remove the chassis cover and the processor air duct. For instructions, see
2. Locate the DIMM(s) and select the ones to be removed. See
.
3. Open the DIMM socket levers.
4. Holding the DIMM by the edges, lift it away from the socket, and store it in an anti-
static package.
5. Replace the air duct and chassis cover if you have completed all work inside of the
server.
3.4.5
Adding or Replacing a Processor
Note:
Use the instructions provided below to add or replace a processor instead of using the
instructions that came with the processor.
Caution:
The processor must be appropriate: You could damage the server board if you install a
processor that is inappropriate for your server. Go to
http://us.kontron.com/support/
for a list of compatible processors for the NSC2U Server.
Before you begin, remove the processor air duct from the chassis. For instructions, tap,
“Removing the Processor Air Duct”
Follow the instructions below to remove and then install a processor, referring to
through
.
3.4.5.1
ESD and Processor Handling Precautions
Be mindful of the following points when handling the processors and sockets:
• Reduce the risk of electrostatic discharge (ESD) damage to the processor by doing
the following:
— Touch the metal chassis before touching the processor or server board.
— Keep part of your body in contact with the metal chassis to dissipate the static
charge while handling the processor.
— Avoid moving around unnecessarily.
— Use a ground strap attached to the front panel (with the bezel removed.)
• When opening a socket, do not touch the gold socket wires.
• When unpacking a processor, hold it only at the edges to avoid touching the gold
contacts.