NSC2U Server—Server Component Installations and Upgrades
Kontron IP Network Server NSC2U
Product Guide, rev. 1.4
December 2009
26
3. Disconnect the power cord(s).
4. Remove the shipping screw, if present.
5. While holding the blue button at the top of the chassis in (“A”), slide the top cover
back until it stops.
6. Lift the cover straight up to remove it from the server.
3.2.2
Installing the Chassis Cover
1. Place the cover over the chassis so that the side edges of the cover sit just inside
the chassis side walls, with the front of the cover with about 1/8-inch (3-mm) gap
showing between the chassis cover and the sheet-metal at the front of the chassis.
2. Press down slightly on the chassis cover behind the peripheral area and slide the
cover forward until it clicks into place.
3. Install the shipping screw if tooled entry is required or if the system will be shipped.
4. Reconnect all peripheral devices and the power cord(s).
Caution:
This unit must be operated only with the top cover installed to ensure proper cooling.
3.2.3
Removing the Front Bezel
Remove the front bezel to
• install or remove hard drives, an optical device, or a 4xGbE connection
• access the front-panel serial port and USB connectors
• observe the individual HDD activity/fault indicators
Note:
The server does not have to be powered down just to remove the front bezel.
1. Disconnect the cables from the front panel 4xGbE connectors if they are installed.
Figure 9.
Removing the Chassis Cover
TS000543
A