NSC2U Server—5
Kontron IP Network Server NSC2U
Product Guide, rev. 1.4
December 2009
110
2. While holding the rear edge of the board, ease the board forward, sliding the serial
port connector and the LED light pipes through the matching cutouts in the front
panel of the chassis.
3. Lower the rear of the board into position, fitting the board over the placement peg.
("B")
4. Push the board forward, locking the board onto the placement peg. ("C")
5. Replace the screw you removed previously. (“D”)
6. Re-install any optional components you removed from the old front panel board,
such as the eUSB SSD or hardware RAID 5 components.
7. Re-install the PCI fan assembly. For instructions, see
Flex Cable to the Backplane Board” on page 107
8. Re-connect the flex cable.
9. Re-install the CPU fan assembly. For instructions, see
.
10. Re-connect all the power cables and the bridge board.
11. Re-connect the RAID IBBU. For instructions, see
Section 4.8.2, “Installing the RAID
Intelligent Battery Backup Unit (IBBU)” on page 93
.
12. If this is the last task you are performing, replace the top cover of the chassis.
Reconnect all the external devices and plug in the power cord(s).
For information about mounting the server in a rack, see
the Server into a Rack” on page 48
.
5.4
Replacing the Removable Drive Bay Assembly and the SAS
Backplane Board
The drive bay assembly can be removed from the chassis and placed in another server
if anything goes wrong in the system or swapped out for another assembly with all the
same HDD drives added to it.
Figure 96.
Installing the Front Panel Board
TS000567
A
B
C
D