Kontron IP Network Server NSC2U
December 2009
Product Guide, rev. 1.4
111
The drive bay assembly is also removed if the SAS backplane board or Power
Distribution Board (PDB) module need to be replaced.
Caution:
Before replacing any of the boards in the NSC2U Server, you must first take the server
out of service, turn off all peripheral devices connected to the system, turn off the
system by pressing the power button, and unplug the power cord(s) from the system
or wall outlet.
5.4.1
Removing the Drive Bay Assembly
1. Disconnect the following cables that are attached to the SAS backplane board at
the rear of the drive bay assembly:
— flex cable
— power cable from the SFP board
— IDE cable from the server board
2. Remove the three screws that attach the drive bay front panel to the side of the
chassis. (
, “A”)
3. Remove the two screws on the right side of the drive bay front panel that attach it
to the chassis front panel. (“B”)
4. Pull the drive bay assembly out of the chassis. (“C”)
Figure 97.
Removing the Drive Bay Assembly
A
B
C
TS000313