![Kontron KISS 4U V3 User Manual Download Page 60](http://html1.mh-extra.com/html/kontron/kiss-4u-v3/kiss-4u-v3_user-manual_1996380060.webp)
KISS 4U V3 SKX – Preliminary Rev. 0.6
www.kontron.com
// 60
11.3.
Mechanical Specification
Table 7: Mechanical Specification
Dimension
KISS 4U V3 SKX
(with front panel &handle brackets)
KISS 4U V3 SKX
(without front panel & handle brackets)
Height (4U)
177 mm (6.97””)
177 mm (6.97”)
Width
483 mm (19”)
430 mm (16.93”)
Depth
515 mm (20.27”)
473 mm (18.62”)
Weight
20 kg (39.6 lbs.) approx.
Chassis
Chassis: RAL 7021
Front panel: RAL 9022 - standard
Front panel: RAL 5017 - option
11.4.
Environmental Specification
Table 8: Environmental Specification
Temperature
Description
Temperature (operating)
0°C … +45°C (32°F ... 113°F )
Temperature (storage)
-20°C … +70°C (-4°F … 158°F )
Humidity (Operating/Storage)
+40 °C @ 93 % non-condensing
Environment
Description
Altitude (operating)
5000 m Max. (16400 ft)
Max. Storage / Transport
Altitude
10000 m (32810 ft)
Shock (operating)
15 g, 11 ms, half sine
Shock (storage)
30 g, 11 ms, half sine
Vibration (operating)
10 – 150 Hz, 1.0 g
Vibration (storage)
0 – 150 Hz, 2.0 g
Acoustic Noise
<= 35dBA
[1]
MTBF
50,000h @ 30°C (min. configuration)
[1]
Minimum configuration, best possible fans, using an optimized distance to ventilation holes and temperature
control fan speed alteration