www.kontron.com
User Guide
CP3004-SA
The airflow is specified in m/s (meter-per-second) or in fps (feet-per-second) respectively.
Conversion: 1 fps = 0.3048 m/s; 1 m/s = 3.28 fps
The following figures illustrate the thermal operational limits of the CP3004-SA taking into consider-
ation power consumption vs. ambient air temperature vs. airflow rate.
Note:
The CP3004-SA must be operated within the thermal operational limits indicated below.
5.1 Operational Limits for the CP3004-SA
Figure 7: CP3004-SA with Intel® Core™ i7-5700EQ, 2.6 GHz
Maximum
Typical
Volumetric Flow Rate (CFM)
Volumetric Flow Rate (m
3
/h)
recommended
operating range
Minimum
Airflow (m/s)
Max.
Airflow Input
T
emp. (°C)