KONRAD 600B SERIES INSTALLATION GUIDE
JANUARY 2019 - V4.0
PAGE 39
Step 7: Trim Control Wiring Installation (continued)
AUX
BAT
BREAKER
5A
PUMP MOTOR
POWER RELAY (UP)
RUDDER SENSOR K.M. P/N 31-053
TRIM
SENSOR K.M. P/N 31-053
1
6
7
MODULE #1
K.M. P/N 13-543
6
7
1
12
*11
DIGITAL DISPLAY K.M. P/N 13-544
TRIM/ LIFT PUMP ASSEMBLY
K.M. P/N 31-063
NOTES: 1) WIRE IDENTIFICATIONS ARE LABELED AS: BK=BLACK, BL=BLUE, RD=RED, PR=PURPLE, GR=GREEN, OR=ORANGE, WT=WHITE, GY=GRAY, YL=YELLOW, TN=TAN, BR=BROWN, PK=PINK 2) ALL WIRES PASSING THROUGH THE CONNECTORS REMAIN THE SAME COLOR
3) (†) MEANS CAVITY IS FILLED WITH A SEAL PLUG
K.M. P/N 13-445 4) CORRESPONDING INDENTIFICATION NUMERICAL CONTACT POINTS ARE IN COMMON FOR TERMINAL STRIP K.M. P/N 11-069 AND 11-070 5) CIRCLED RD BK SYMBOLS INDICATE THE WIRE IS TWISTED PAIR.
*14
GR
BL
DRAWING BY A.G. AUGUST 2015 REVISION 1 JUNE 2016
K.M. P/N 13-438
K.M. P/N 11-065
1
2
3
4
5
6
1
2
3
4
5
6
1
1
2
2
3
3
4
4
BK
BK
HARNESS K.M. P/N 31-051
*13
12
1
12
1
12
K.M. P/N 13-610
K.M. P/N 13-585
KEYPAD
THROTTLE TRIM 2 (UP)
THROTTLE TRIM 2 (DN)
THROTTLE TRIM 3 (DN)
NEGATIVE/ GROUND
HOT/ POSITIVE (8-32VDC)
KEYSWITCH
PANEL ILLUMINATION
THROTTLE TRIM 1 (UP)
THROTTLE TRIM 1 (DN)
3
2
4
1
2
1
4
3
NEGATIVE/ GROUND
HOT/ POSITIVE (8-32VDC)
OIL RESERVOIR LOW OIL SWITCH
CONNECT TO NEGATIVE/GROUND SIDE OF 12VDC CIRCUIT
CONNECT TO POSITIVE SIDE OF 12VDC CIRCUIT 100(AMP)
NOTE: CONDUCTOR/ WIRES NOT SUPPLIED BY KONRAD MARINE
TRIM PUMP #1
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
C
A
B
A
B
C
A
C
A
B
C
A
B
C
A
B
C
A
B
C
C
B
A
C
B
A
B
C
A
A
C
B
A
C
A
B
C
A
B
C
C
C
A
B
A
B
C
A
B
A
B
C
6
12
18
13
7
1
1
7
13
6
12
18
7
6
6
7
RD
BK
BK
BK
YL
RD
BK
YL
RD
RD
RD
RD
RD
YL
PR
PR
4 POSITION TERMINAL STRIP K.M. P/N 11-070
YL
PR
YL
GY
RD
PK
BL
TN
GR
BK
RD
BK
RD
BK
GR
GY
TN
WT
PK
OR
PR
YL
CONNECTING HARNESS
10'(3M) K.M. P/N 31-057 20'(6.1M) K.M. P/N 31-058 30'(9.1M) K.M. P/N 31-059 40'(12.2M) K.M. P/N 31-060
CONNECTING
HARNESS
6'(1.8M) K.M. P/N 31-061 10'(3M) K.M. P/N 31-057 14'(4.3M) K.M. P/N 31-062
*1
*2
*4
*5
*6
*7
*8
*9
*12
*10
*28
*27
*25
*26
*24
*23
*21
*22
*19
*20
K.M. P/N 10-528
POWER RELAY (DN)
K.M. P/N 10-430
THROTTLE TRIM 3 (UP)
B
*18
*17
*16
*15
C
A
B
C
A
B
A
C
B
A
B
C
A
B
C
C
B
A
B
A
C
*3
CONNECTING HARNESS FROM TRIM PUMP #2 & MODULE #2 (13-697)
CONNECTING HARNESS FROM TRIM PUMP#3 & MODULE #3 (13-698)
B
CONNECTING
HARNESS
6'(1.8M) K.M. P/N 31-061 10'(3M) K.M. P/N 31-057 14'(4.3M) K.M. P/N 31-062
CONNECTING HARNESS
K.M. P/N 31-108
KONRAD MARINE INC. TRIM SYSTEM ELECTRICAL DRAWING (12 VOLT) 600B TRIPLE DRIVE
HARNESS K.M. P/N 31-054
NOTES FOR HARNESS K.M. P/N 31-054: 1) ALL WIRES ARE PIGTAILED AND TO BE ROUTED/CONNECTED TO DESIGN
ATED LOCATION.
2) ALL THROTTLE CONTOL WIRES ARE INCLUDED(COMPATIABLE WITH UP T
O 3 THROTTLE TRIM
SWITCHES); HOWEVER, NOT ALL APPLICATIONS WILL UTILIZE ANY OR AL
L OF THE WIRES.
3) FOR THROTTLE TRIM APPLICATION WIRING INSTALLATION REFER TO T
HE 600B INSTALATION
MANUAL.
RESISTOR K.M. P/N 13-599
K.M. P/N 30-992
MOMENTARY (ON) OFF (ON) TOGGLE SWITCH TRIM OVERRIDE
BK
BK
BK
LOCATED ON
GIMBAL ASSSEMBLY
†
†
†
†
†
†
†
†
†
†
†
†
†
†
†
†
†
†
†
†
†
†
RD
BK
BK
RD
BK
RD
BK
RD
BK
RD
BK
RD
RESISTOR K.M. P/N 13-599
Y-CONNECTOR K.M. P/N 13-457
Y-CONNECTOR K.M. P/N 13-457
Y-CONNECTOR K.M. P/N 13-457
†
CONNECTOR *#
DESCRIPTION
MATING
CONNECTOR
*1
18 CAVITY FEMALE
*2
*2
18 CAVITY MALE
*1
*3
3 CAVITY MALE
*4
*4
3 CAVITY,3 WAY FEMALE Y
*3,*5,*6
*5
3 CAVITY MALE
*4
*6
3 CAVITY MALE
*4
*7
3 CAVITY MALE
*8
*8
3 CAVITY,3 WAY FEMALE Y
*7,*9,*10
*9
3 CAVITY MALE
*8
*10
3 CAVITY MALE
*8
*11
12 CAVITY FEMALE
*12
*12
12 CAVITY MALE
*11
*13
12 CAVITY MALE
*14
*14
12 CAVITY FEMALE
*13
*15
3 CAVITY MALE
*16
*16
3 CAVITY,3 WAY FEMALE Y
*15,*17,*18
*17
3 CAVITY MALE
*16
*18
3 CAVITY MALE
*16
*19
4 CAVITY MALE
*20
*20
4 CAVITY FEMALE
*19
*21
3 CAVITY MALE
*23
*22
3 CAVITY MALE
*23
*23
3 CAVITY,3 WAY FEMALE Y
*21,*22,*24
*24
3 CAVITY MALE
*23
*25
3 CAVITY MALE
*27
*26
3 CAVITY MALE
*27
*27
3 CAVITY,3 WAY FEMALE Y
*25,*26,*28
*28
3 CAVITY MALE RESISTOR
*27