Field Service Ver. 1.0 Dec. 2008
11. Soft Switch Settings
111
FK-503
ADJUSTMENT/
SETTING
NOTE
• The features with (*) are settable by users. *: Screen setting
MODE
Factory setting bit
355
Bit:
7
6
5
4
3
2
1
0
0
0
1
0
0
0
0
0
HEX:20
Bit
Feature
Logic
Description
0
1
7
Switch 10M and 100M:
Select communication
rate of LAN adapter (Net-
work function) *
Bit7-6:
00
Auto-negoti-
ation
• Auto-negotiation:
Determine the com-
munication rate by
identifying 10BASE-T
or 100BASE-TX.
• Set to 100M: Connec-
tion is set to
100BASE-TX.
• Set to 10M: Connec-
tion is set to 10BASE-
T.
Valid after the power is
turned off and on.
(Will not communicate
when “Set to 100M” or
“Set to 10M” is chosen
and the communication
rate is not correct for the
communication line.
Check and specify the
correct communication
rate for the line.)
6
01
Set to 100M
10
Set to 10M
11
Not available
5
Switch full-duplex and
half-duplex:
Select packet transmit/
receive when connecting
to switching hub.
(Network function) *
Full
Duplex
Half
Duplex
This switch is valid when MODE 355 Bit
7 to 6 is set to “Set to 100M” or “Set to
10M”.
• Full-duplex: Packets can be sent and
received simultaneously.
• Half-duplex: Packets can be sent or
received separately.
Valid after the main power switch is
turned off and on.
4
Automatically obtain IP
address (DHCP) *
No
Yes
Summary of Contents for Bizhub 222
Page 21: ...SAFETY AND IMPORTANT WARNING ITEMS S 18 A11UP0C504DA High voltage ...
Page 26: ...SERVICE MANUAL 2008 12 Ver 1 0 FIELD SERVICE Main body ...
Page 151: ...6 Other Field Service Ver 1 0 Dec 2008 112 bizhub 362 282 222 MAINTENANCE Blank Page ...
Page 349: ...24 Timing chart Field Service Ver 1 0 Dec 2008 310 bizhub 362 282 222 APPENDIX 4040F5E522DA ...
Page 352: ...SERVICE MANUAL 2008 12 Ver 1 0 FIELD SERVICE Duplex Unit Switchback Unit ...
Page 370: ...SERVICE MANUAL 2008 12 Ver 1 0 FIELD SERVICE Standard Controller ...
Page 382: ...SERVICE MANUAL 2008 12 Ver 1 0 FIELD SERVICE FK 503 ...
Page 391: ...1 Product specifications Field Service Ver 1 0 Dec 2008 4 FK 503 OUTLINE Blank Page ...
Page 397: ...4 Disassembly Reassembly Field Service Ver 1 0 Dec 2008 10 FK 503 MAINTENANCE Blank Page ...
Page 606: ...SERVICE MANUAL 2008 12 Ver 1 0 FIELD SERVICE DF 620 ...
Page 613: ...1 Product specifications Field Service Ver 1 0 Dec 2008 4 DF 620 OUTLINE Blank Page ...
Page 643: ...10 Set error detection Field Service Ver 1 0 Dec 2008 34 DF 620 TROUBLESHOOTING Blank Page ...
Page 644: ...SERVICE MANUAL 2008 12 Ver 1 0 FIELD SERVICE PC 108 PC 206 ...
Page 649: ...1 Product specifications Field Service Ver 1 0 Dec 2008 2 PC 108 PC 206 OUTLINE Blank Page ...
Page 675: ...8 Trouble code Field Service Ver 1 0 Dec 2008 28 PC 108 PC 206 TROUBLESHOOTING Blank Page ...
Page 676: ...SERVICE MANUAL 2008 12 Ver 1 0 FIELD SERVICE PC 407 ...
Page 681: ...1 Product specification Field Service Ver 1 0 Dec 2008 2 PC 407 OUTLINE Blank Page ...
Page 695: ...3 Other Field Service Ver 1 0 Dec 2008 16 PC 407 MAINTENANCE Blank Page ...
Page 715: ...8 Trouble code Field Service Ver 1 0 Dec 2008 36 PC 407 TROUBLESHOOTING Blank Page ...
Page 716: ...SERVICE MANUAL 2008 12 Ver 1 0 FIELD SERVICE JS 502 ...
Page 719: ...JS 502 OUTLINE MAINTENANCE ADJUSTMENT SETTING Field Service Ver 1 0 Dec 2008 ii Blank Page ...
Page 721: ...1 System configuration Field Service Ver 1 0 Dec 2008 2 JS 502 OUTLINE Blank Page ...
Page 726: ...SERVICE MANUAL 2008 12 Ver 1 0 FIELD SERVICE FS 530 PU 501 OT 602 ...
Page 780: ...SERVICE MANUAL 2008 12 Ver 1 0 FIELD SERVICE MT 502 ...
Page 785: ...1 Product specification Field Service Ver 1 0 Dec 2008 2 MT 502 OUTLINE Blank Page ...
Page 798: ...SERVICE MANUAL 2008 12 Ver 1 0 FIELD SERVICE SD 507 ...
Page 803: ...1 Product specifications Field Service Ver 1 0 Dec 2008 2 SD 507 OUTLINE Blank Page ...
Page 829: ...4 Other Field Service Ver 1 0 Dec 2008 28 SD 507 MAINTENANCE Blank Page ...