10. Tech. Rep. Mode
Field Service Ver. 1.0 Dec. 2008
160
bizhub 362/282/222
ADJUSTMENT/
SETTING
C. Image Density
D. ATDC Sensor Gain
E. Grid Voltage Adjustment
Functions
• To change the Vg and Vb of the engine to select the image density.
Use
• When the image density is high or low:
• With the Printing Density setting specified in User’s Choice as a reference point, the
density can be set to one of seven settings.
Adjustment
Range
• The default setting is “0”.
• The adjustment range is -3 mm to +3 mm. (in 1 mm increments)
Adjustment
Instructions
If the image density is high, decrease the setting value.
If the image density is low, increase the setting value.
Adjustment
Procedure
1.
Call the Tech. Rep. Mode to the screen.
2.
Touch the keys in this order: [Tech. Rep. Choice]
→
[Printer]
→
[Image density].
3.
Press the Clear key and change the setting value using the 10-Key Pad.
4.
Change the + or - sign using the Access key or * key.
5.
Touch [END] to validate the new setting value.
Functions
• To display the value automatically adjusted using function F8 and to change that value.
Use
• When the spare Developing Unit or the Imaging Unit has been temporarily used
<Current>
• ATDC control voltage automatically adjusted using function F8
<Job Setting>
• Normally, the value displayed here is the same as that displayed for Current.
NOTE
• If a Developing Unit other than a new one is installed, type in the setting for the
installed product.
Adjustment
Range
• The adjustment range is 0 to 255.
Adjustment
Procedure
1.
Call the Tech. Rep. Mode to the screen.
2.
Touch the keys in this order: [Tech. Rep. Choice]
→
[Printer]
→
[ATDC Sensor Gain].
3.
Press the Clear key and change the setting value using the 10-Key Pad
4.
Touch [END] to validate the new setting value.
Functions
• To change the Vg setting for sensitivity variations due to the durability of the PC Drum
and adjust the image density.
Use
• When the PC Drum Unit is replaced
• If a foggy background occurs, increase the setting value.
Adjustment
Range
• The default setting is “0”.
• The adjustment range is -2 to +2.
Adjustment
Procedure
1.
Call the Tech. Rep. Mode to the screen.
2.
Touch the keys in this order: [Tech. Rep. Choice]
→
[Printer]
→
[Grid Voltage Adjust-
ment].
3.
Press the Clear key and change the setting value using the 10-Key Pad
4.
Touch [END] to validate the new setting value.
Summary of Contents for Bizhub 222
Page 21: ...SAFETY AND IMPORTANT WARNING ITEMS S 18 A11UP0C504DA High voltage ...
Page 26: ...SERVICE MANUAL 2008 12 Ver 1 0 FIELD SERVICE Main body ...
Page 151: ...6 Other Field Service Ver 1 0 Dec 2008 112 bizhub 362 282 222 MAINTENANCE Blank Page ...
Page 349: ...24 Timing chart Field Service Ver 1 0 Dec 2008 310 bizhub 362 282 222 APPENDIX 4040F5E522DA ...
Page 352: ...SERVICE MANUAL 2008 12 Ver 1 0 FIELD SERVICE Duplex Unit Switchback Unit ...
Page 370: ...SERVICE MANUAL 2008 12 Ver 1 0 FIELD SERVICE Standard Controller ...
Page 382: ...SERVICE MANUAL 2008 12 Ver 1 0 FIELD SERVICE FK 503 ...
Page 391: ...1 Product specifications Field Service Ver 1 0 Dec 2008 4 FK 503 OUTLINE Blank Page ...
Page 397: ...4 Disassembly Reassembly Field Service Ver 1 0 Dec 2008 10 FK 503 MAINTENANCE Blank Page ...
Page 606: ...SERVICE MANUAL 2008 12 Ver 1 0 FIELD SERVICE DF 620 ...
Page 613: ...1 Product specifications Field Service Ver 1 0 Dec 2008 4 DF 620 OUTLINE Blank Page ...
Page 643: ...10 Set error detection Field Service Ver 1 0 Dec 2008 34 DF 620 TROUBLESHOOTING Blank Page ...
Page 644: ...SERVICE MANUAL 2008 12 Ver 1 0 FIELD SERVICE PC 108 PC 206 ...
Page 649: ...1 Product specifications Field Service Ver 1 0 Dec 2008 2 PC 108 PC 206 OUTLINE Blank Page ...
Page 675: ...8 Trouble code Field Service Ver 1 0 Dec 2008 28 PC 108 PC 206 TROUBLESHOOTING Blank Page ...
Page 676: ...SERVICE MANUAL 2008 12 Ver 1 0 FIELD SERVICE PC 407 ...
Page 681: ...1 Product specification Field Service Ver 1 0 Dec 2008 2 PC 407 OUTLINE Blank Page ...
Page 695: ...3 Other Field Service Ver 1 0 Dec 2008 16 PC 407 MAINTENANCE Blank Page ...
Page 715: ...8 Trouble code Field Service Ver 1 0 Dec 2008 36 PC 407 TROUBLESHOOTING Blank Page ...
Page 716: ...SERVICE MANUAL 2008 12 Ver 1 0 FIELD SERVICE JS 502 ...
Page 719: ...JS 502 OUTLINE MAINTENANCE ADJUSTMENT SETTING Field Service Ver 1 0 Dec 2008 ii Blank Page ...
Page 721: ...1 System configuration Field Service Ver 1 0 Dec 2008 2 JS 502 OUTLINE Blank Page ...
Page 726: ...SERVICE MANUAL 2008 12 Ver 1 0 FIELD SERVICE FS 530 PU 501 OT 602 ...
Page 780: ...SERVICE MANUAL 2008 12 Ver 1 0 FIELD SERVICE MT 502 ...
Page 785: ...1 Product specification Field Service Ver 1 0 Dec 2008 2 MT 502 OUTLINE Blank Page ...
Page 798: ...SERVICE MANUAL 2008 12 Ver 1 0 FIELD SERVICE SD 507 ...
Page 803: ...1 Product specifications Field Service Ver 1 0 Dec 2008 2 SD 507 OUTLINE Blank Page ...
Page 829: ...4 Other Field Service Ver 1 0 Dec 2008 28 SD 507 MAINTENANCE Blank Page ...