Thanks to long term experience and ample data accumulated, we can grasp condition of your machine accu-
rately and provide proper recommendation.
We strongly recommend you to use this service. The oil analysis is performed at actual cost, so the cost is low,
and results of the analysis and recommendations are reported promptly.
KOWA analysis items
Measurement of metallic powder concentration
An ICP (Inductively Coupled Plasma) analyzer is used for
measuring the concentration of iron, copper, and other metal
powder in the oil.
Measurement of quantity of iron particles
A PQI (Particle Quantifier Index) measuring instrument is used
for measuring the quantity of iron particles of 5 μm or more, en-
abling early detection of failures.
Others
Measurements are made of items such as the ratio of water, coolant, and fuel in the oil, and dynamic viscosity, if
necessary, to enable a highly precise diagnosis of the machine and the components' condition.
Oil sampling interval
500 hours
Precautions when sampling
• Make sure that the oil is well mixed before sampling.
• Perform sampling at regular fixed intervals.
• Do not perform sampling on rainy or windy days when water or dust can get into the oil.
For further details of KOWA, contact your Komatsu distributor.
STORE OIL AND FUEL
• Keep oil and fuel indoors to prevent any water, dirt, or other impurities from getting in.
• When keeping drum cans for a long period, lay the drums so that the filler ports of the drums are located in
the lower part of the side to prevent moisture from being sucked in. If drums have to be stored outside, cov-
er them with a waterproof sheet or take other measures to protect them.
• To prevent any change in quality during long-term storage, be sure to use in the order of first in - first out
(use the oldest oil or fuel first).
FILTER
• Filters are extremely important safety parts. They prevent impurities in the oil, fuel, and air circuits from en-
tering important equipment and causing problems. Replace all filters periodically. For details, see Operation
and Maintenance Manual.
However, when working in severe conditions, replace the filters at shorter intervals according to the oil and
fuel (sulfur content) being used.
OUTLINE OF MAINTENANCE
MAINTENANCE
4-6
WENAM00061
Summary of Contents for PW98MR-10
Page 1: ......
Page 2: ......
Page 9: ...Do not repeatedly handle and lift loads FOREWORD VIBRATION LEVELS 1 7 WENAM00061...
Page 68: ...WENAM00061...
Page 73: ...CONTROLS AND GAUGES NAMES OPERATION GENERAL VIEW 3 5 WENAM00061...
Page 157: ...SWITCHES OPERATION EXPLANATION OF COMPONENTS 3 89 WENAM00061...
Page 388: ...WENAM00061...
Page 389: ...SPECIFICATIONS 5 1 WENAM00061...
Page 392: ...RKA55390 SPECIFICATIONS SPECIFICATIONS 5 4 WENAM00061...
Page 402: ...WENAM00061...
Page 428: ...WENAM00061...
Page 429: ...REPLACEMENT PARTS 7 1 WENAM00061...
Page 445: ......
Page 446: ......